Our duct furnaces can be ordered with several different options so they fit your specific requirements.
Furnace makeup air requirements.
According to the u s.
Likewise if the outside air temperature is 10 f then the ventilation fan is bringing in 10 f air.
Makeup air for kitchen exhaust.
Several options are also available for the outdoor and indirect indoor make up air unit.
Makeup air if you have a conventional furnace not high efficiency you can make a simple one by installing a dryer vent in the wall to outside about 2 1 2 ft above the floor pipe it to the area of the burners down into a 5 gallon bucket stopping about 5 inches above the bottom of the pail if your in a colder area insulate the pipe.
Of air per minute require makeup air so they don t depressurize the home and draw combustion gases from the appliance into the living space.
The makeup air system consists of a make up air damper mounted on the return air duct of an hvac system and an intake air hood installed through an exterior wall to allow outdoor air into the home with the two being typically connected by installer supplied standard 6 galvanized sheet metal pipe.
If an exhaust fan rated over 300 cfm is installed makeup air might be needed and a calculation will need to be done.
Makeup air shall be mechanically or naturally provided makeup air systems shall be equipped with not less than one damper gravity dampers electrically operated damper that automatically opens when the exhaust system operates 26 2015 requirements adopted in pa.
In addition our indoor outdoor direct fired make up air unit is an efficient way to supply tempered make up air to your space.
A furnace must be supplied a specific amount of fresh air per cubic foot of gas burned.
Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system.
With a make up air unit that same 10 f air can be tempered to 50 f.
The real requirement is that makeup air must be provided if it s needed.
Exhaust hood systems capable of exhausting in excess of 400 cfm 0 19 m 3 s shall be provided with makeup air at a rate approximately equal to the exhaust air rate.
This means the heating system wouldn t be required to work any harder than is necessary nor would it waste energy.
By glenn mathewson issue 287 kitchens baths.
Ten cubic feet of air contains 2 cubic feet of oxygen and 8 cubic feet of nitrogen and other gases combined with water vapor.
To burn 1 cubic foot of gas approximately 1 000 btu for natural gas requires 10 cubic feet of air for perfect combustion figure 2.